Specifies the noise compensation type.

Syntax

RFMXNR_ATTR_ACP_NOISE_COMPENSATION_TYPE

Numeric Value

Data Type

Access

Applies To

9441353

Int32

Read/Write

N/A

Remarks


Refer to the measurement guidelines section in the Noise Compensation Algorithm topic for more information.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is Analyzer and Termination.

Name

Value

Description

RFMXNR_VAL_ACP_NOISE_COMPENSATION_TYPE_ANALYZER_AND_TERMINATION

0 (0x0)

Compensates for noise from the analyzer and the 50-ohm termination. The measured power values are in excess of the thermal noise floor.

RFMXNR_VAL_ACP_NOISE_COMPENSATION_TYPE_ANALYZER_ONLY

1 (0x1)