Specifies whether to enable averaging for the ACP measurement.

Syntax

RFMXNR_ATTR_ACP_AVERAGING_ENABLED

Numeric Value

Data Type

Access

Applies To

9441310

int32

Read/Write

N/A

Remarks


You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

Name

Value

Description

RFMXNR_VAL_ACP_AVERAGING_ENABLED_FALSE

0 (0x0)

The measurement is performed on a single acquisition.

RFMXNR_VAL_ACP_AVERAGING_ENABLED_TRUE

1 (0x1)

The ACP measurement uses the value of the RFMXNR_ATTR_ACP_AVERAGING_COUNT attribute as the number of acquisitions over which the ACP measurement is averaged.