RFmxLTE SEM Configure Offset Frequency VI
- Updated2025-04-08
- 3 minute(s) read
Configures the start and stop frequencies and the sideband of an offset segment.
Use "offset<n>" or "subblock<n>/offset<n>" as the selector string to configure from this VI.

Inputs/Outputs
![]() Selector String specifies a selector string comprising of the signal name, subblock number, and offset number. If you do not specify the signal name, the default signal instance is used. Example: "subblock0/offset0" "signal::sig1/subblock0/offset0" You can use the RFmxLTE Build Offset String VI to build the selector string. ![]() Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI. ![]() Offset Start Freq specifies the start frequency of an offset segment relative to the carrier channel bandwidth edge (single-carrier) or the subblock aggregated channel bandwidth edge (multi-carrier). This value is expressed in Hz. The default value is 0. ![]() Offset Stop Freq specifies the stop frequency of an offset segment relative to the carrier channel bandwidth edge (single-carrier) or the subblock aggregated channel bandwidth edge (multi-carrier). This value is expressed in Hz. The default value is 1 MHz. ![]() Offset Sideband specifies whether the offset segment is present on one side, or on both sides of the carrier. The default value is Both.
![]() error in describes error conditions that occur before this node runs. This input provides standard error in functionality. ![]() Instrument Handle Out passes a reference to your RFmx session to the next VI. ![]() error out contains error information. This output provides standard error out functionality. |