Fetches the EVM values calculated on NPUSCH DMRS over the length of the measurement.

Use "carrier<k>" or "subblock<n>/carrier<k>" as the selector string to configure this VI.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name, result name, subblock number, and carrier number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "subblock0/carrier0".

    Example:

    "subblock0/carrier0"

    "signal::sig1/subblock0/carrier0"

    "result::r1/subblock0/carrier0"

    "signal::sig1/result::r1/subblock0/carrier0"

    You can use the RFmxLTE Build Carrier String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • idbl.png NPUSCH Mean RMS DMRS EVM (% or dB)

    NPUSCH Mean RMS DMRS EVM returns the mean value of the RMS EVMs calculated on the NPUSCH DMRS over the slots specified by the ModAcc Meas Length property.

    When you set the ModAcc EVM Unit property to Percentage, the result is returned as a percentage, and when you set the ModAcc EVM Unit property to dB, the result is returned in dB.

  • idbl.png NPUSCH Maximum Peak DMRS EVM (% or dB)

    NPUSCH Maximum Peak DMRS EVM returns the maximum value of the peak EVMs calculated on NPUSCH DMRS over the slots specified by the ModAcc Meas Length property.

    When you set the ModAcc EVM Unit property to Percentage, the result is returned as a percentage, and when you set the ModAcc EVM Unit property to dB, the result is returned in dB.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.