Configures the Reference Clock and specifies whether same Reference Clock is used for local oscillator and D/A converter.

The modacc measurement ignores this VI, when you set the Link Direction property to Downlink.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default is "" (empty string).

    Example:

    "signal::sig1"

    You can use the RFmxLTE Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • ci32.png Common Clock Source Enabled

    Common Clock Source Enabled specifies whether the same Reference Clock is used for the local oscillator and the D/A converter. When the same Reference Clock is used, the carrier frequency offset is proportional to the Sample Clock error. The default value is True.

    False (0)

    The Sample Clock error is estimated independently.

    True (1)

    The Sample Clock error is estimated from carrier frequency offset.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.