Configures averaging for the ModAcc measurement.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default is "" (empty string).

    Example:

    "signal::sig1"

    You can use the RFmxLTE Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • ci32.png Averaging Enabled

    Averaging Enabled specifies whether to enable averaging for the measurement. The default value is False.

    False (0)

    The measurement is performed on a single acquisition.

    True (1)

    The measurement is averaged over multiple acquisitions. The number of acquisitions is obtained by the Averaging Count parameter.

  • ci32.png Averaging Count

    Averaging Count specifies the number of acquisitions used for averaging when you set the Averaging Enabled parameter to True. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • ierrcodeclst.png error out