RFmxLTE Configure PDCCH VI
- Updated2025-04-08
- 2 minute(s) read
Configures the physical downlink control channel (PDCCH) power relative to the cell-specific reference signal.
Use "carrier<k>" or "subblock<n>/carrier<k>" as the selector string to configure this VI.

Inputs/Outputs
![]() Selector String specifies a selector string comprising of the signal name, subblock number and carrier number. If you do not specify the signal name, the default signal instance is used. The default value is "subblock0/carrier0". Example: "subblock0/carrier0" "signal::sig1/subblock0/carrier0" You can use the RFmxLTE Build Carrier String VI to build the selector string. ![]() Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI. ![]() PDCCH Power specifies the power of the PDCCH relative to the power of the cell-specific reference signal. This value is expressed in dB. The default value is 0. ![]() error in describes error conditions that occur before this node runs. This input provides standard error in functionality. ![]() Instrument Handle Out passes a reference to your RFmx session to the next VI. ![]() error out contains error information. This output provides standard error out functionality. |