Configures the EUTRA test model type.

Use "carrier<k>" or "subblock<n>/carrier<k>" as the selector string to configure this VI.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name, subblock number and carrier number. If you do not specify the signal name, the default signal instance is used. The default value is "subblock0/carrier0".

    Example:

    "subblock0/carrier0"

    "signal::sig1/subblock0/carrier0"

    You can use the RFmxLTE Build Carrier String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • ci32.png DL Test Model

    DL Test Model specifies the EUTRA test model type when you set the DL Ch Configuration Mode property to Test Model. Refer to section 6.1.1 of the 3GPP 36.141 specification for more information regarding test model configurations. The default value is TM1.1.

    TM1.1 (0)

    Specifies an E-UTRA Test Model 1.1.

    TM1.2 (1)

    Specifies an E-UTRA Test Model 1.2.

    TM2 (2)

    Specifies an E-UTRA Test Model 2.

    TM2a (3)

    Specifies an E-UTRA Test Model 2a.

    TM2b (8)

    Specifies an E-UTRA Test Model 2b.

    TM3.1 (4)

    Specifies an E-UTRA Test Model 3.1.

    TM3.1a (7)

    Specifies an E-UTRA Test Model 3.1a.

    TM3.1b (9)

    Specifies an E-UTRA Test Model 3.1b.

    TM3.2 (5)

    Specifies an E-UTRA Test Model 3.2.

    TM3.3 (6)

    Specifies an E-UTRA Test Model 3.3.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • ierrcodeclst.png error out