Specifies whether the measurement is performed from the frame or the slot boundary.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is Slot.

Remarks

The following table lists the characteristics of this property.

Short Name SlotPhase Sync Mode
Data type ci32.png
Permissions Read/Write
High-level VIs RFmxLTE SlotPhase Configure Synchronization Mode and Interval
Resettable Yes
Frame 0

The frame boundary in the acquired signal is detected, and the measurement is performed over the number of slots specified by the SlotPhase Meas Length property, starting at the offset from the boundary specified by the SlotPhase Meas Offset property. When the Trigger Type property is set to Digital, the measurement expects a trigger at the frame boundary.

Slot 1

The slot boundary in the acquired signal is detected, and the measurement is performed over the number of slots specified by the SlotPhase Meas Length property, starting at the offset from the boundary specified by the SlotPhase Meas Offset property. When the Trigger Type property is set to Digital, the measurement expects a trigger at any slot boundary.