Specifies the cyclic prefix (CP) duration and the number of symbols in a slot for the signal being measured.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is Normal.

Remarks

The following table lists the characteristics of this property.

Short Name Cyclic Prefix Mode
Data type ci32.png
Permissions Read/Write
High-level VIs N/A
Resettable Yes
Normal 0

The CP duration is 4.67 microseconds, and the number of symbols in a slot is 7.

Extended 1