GetMeanSymbolClockError(string, out double)
- Updated2025-10-13
- 1 minute(s) read
Gets the estimated symbol clock error averaged over the slots specified by the SetMeasurementLength(string, int) method. This value is expressed in ppm. Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read this result.
Syntax
Namespace: NationalInstruments.RFmx.LteMX
public int GetMeanSymbolClockError(string selectorString, out double value)
Remarks
This method gets the value of ModAccResultsMeanSymbolClockError attribute.
Parameters
| Name | Type | Description |
|---|---|---|
| selectorString | string | Specifies the result name, Carrier number and Subblock number. Example: "Subblock0", "result::r1/Subblock0" or "result::r1/Subblock0/Carrier0". You can use the BuildCarrierString(string, int) method to build the selector string. |
| value | out double | Upon return, contains the estimated symbol clock error averaged over the slots specified by the SetMeasurementLength(string, int) method. This value is expressed in ppm. Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read this result. |
Returns
Returns the status code of this method. The status code either indicates success or describes a warning condition.