Gets the estimated symbol clock error averaged over the slots specified by the SetMeasurementLength(string, int) method. This value is expressed in ppm. Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read this result.

Syntax

Namespace: NationalInstruments.RFmx.LteMX

public int GetMeanSymbolClockError(string selectorString, out double value)

Remarks

This method gets the value of ModAccResultsMeanSymbolClockError attribute.

Parameters

NameTypeDescription
selectorStringstring

Specifies the result name, Carrier number and Subblock number. Example: "Subblock0", "result::r1/Subblock0" or "result::r1/Subblock0/Carrier0". You can use the BuildCarrierString(string, int) method to build the selector string.

valueout double

Upon return, contains the estimated symbol clock error averaged over the slots specified by the SetMeasurementLength(string, int) method. This value is expressed in ppm. Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read this result.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.