Fetches the physical sidelink shared channel (PSSCH) data symbols power and DMRS symbols power.
Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read results from this method.

Syntax

Namespace: NationalInstruments.RFmx.LteMX

public int FetchPsschSymbolPower(string selectorString, double timeout, out double psschMeanDataPower, out double psschMeanDmrsPower)

Parameters

NameTypeDescription
selectorStringstring

Specifies a selector string comprising of the result name, subblock number, and carrier number. If you do not specify the result name, the default result instance is used. Example:
"subblock0/carrier0"
"result::r1/subblock0/carrier0"
You can use the BuildCarrierString(string, int) method to build the selector string.

timeoutdouble

Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.

psschMeanDataPowerout double

Upon return, contains the mean value of the power calculated on the PSSCH data symbols over the slots specified by the SetMeasurementLength(string, int) method. This value is expressed in dBm.

psschMeanDmrsPowerout double

Upon return, contains the mean value of the power calculated on the PSSCH DMRS symbols over the slots specified by the ModAcc Meas Length method. This value is expressed in dBm.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.