RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PSS_EVM
- Updated2025-04-08
- 1 minute(s) read
Returns the mean value of RMS EVMs calculated on primary synchronization signal (PSS) channel over the slots specified by the RFMXLTE_ATTR_MODACC_MEASUREMENT_LENGTH attribute.
Syntax
RFMXLTE_ATTR_MODACC_RESULTS_MEAN_RMS_PSS_EVM
Numeric Value | Data Type | Access | Applies To |
---|---|---|---|
3162186 | float64 | Read-Only | Carrier |
Remarks
When you set the RFMXLTE_ATTR_MODACC_EVM_UNIT attribute to Percentage, the measurement returns this result as a percentage. When you set the ModAcc EVM Unit attribute to dB, the measurement returns this result in dB.
Use "carrier<k>" or "subblock<n>/carrier<k>" as the selector string to read this result.