RFMXINSTR_ATTR_LO_EXPORT_ENABLED
- Updated2025-10-13
- 1 minute(s) read
Specifies whether to enable the LO OUT terminals on the installed devices.
Syntax
RFMXINSTR_ATTR_LO_EXPORT_ENABLED
Numeric Value | Data Type | Access | Applies To |
|---|---|---|---|
33 | int32 | Read/Write | Lo |
Remarks
Name (value) | Description |
|---|---|
TRUE | Enables the LO OUT terminals. |
FALSE | Disables the LO OUT terminals |
This attribute is not supported on a MIMO session.
You do not need to use a selector string if you want to configure this attribute for all signal instances. Specify the signal name in the selector string if you want to configure or read on that signal instance. Refer to the Selector String topic for information about the string syntax.
PXIe-5663/5663E: TRUE
PXIe-5644/5645/5646, PXIe-5665/5668, PXIe-5830/5831/5832/5840/5841/5842: FALSE
Supported devices: PXIe-5644/5645/5646, PXIe-5663/5663E/5665/5668, PXIe-5830/5831/5832/5840/5841/5842