Specifies the list of frequency offsets for which you can perform the output radio frequency spectrum (ORFS) measurements.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is Standard.

Remarks

The following table lists the characteristics of this property.

Short Name ORFS Offset Freq Mode
Data type ci32.png
Permissions Read/Write
High-level VIs RFmxGSM ORFS Configure Offset Frequency Mode
Resettable Yes
Standard 0

Uses the list of lower and upper offset frequencies of 100 kHz, 200 kHz, 250 kHz, 400 kHz, 600 kHz, 800 kHz, 1000 kHz, 1200 kHz, 1400 kHz, 1600 kHz, and 1800 kHz for the spectrum due to the modulation measurement, and the lower and upper offset frequencies of 400 kHz, 600 kHz, 1200 kHz, and 1800 kHz for the spectrum produced by the switching measurement.

Short 1

Uses the list of lower and upper offset frequencies of 200 kHz, 250 kHz, 400 kHz, 600 kHz, and 1200 kHz for the spectrum due to the modulation measurement, and the lower and upper offset frequencies of 400 kHz, 600 kHz, 1200 kHz, and 1800 kHz for the spectrum produced by the switching measurement.

Custom 2

Uses the list of frequencies that is configured using the RFmxGSM ORFS Configure Modulation Custom Offset Frequency (Array) and RFmxGSM ORFS Configure Switching Custom Offset Frequency (Array) VIs for measurement of spectrum produced by modulation and switching measurements.