Returns the absolute and relative powers measured in the carriers. The relative powers are measured relative to the integrated power of the power reference carrier. Use "carrier<n>" as the selector string to read results from this VI.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name, result name, and carrier number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used.

    Examples:

    "carrier0"

    "signal::sig1/carrier0"

    "result::r1/carrier0"

    "signal::sig1/result::r1/carrier0"

    You can use the RFmxEVDO Build Carrier String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • idbl.png Carrier Absolute Power (dBm)

    Carrier Absolute Power returns the absolute carrier power of the selected carrier. This value is expressed in dBm.

  • idbl.png Carrier Relative Power (dB)

    Carrier Relative Power returns the relative carrier power of the selected carrier. This value is expressed in dBm.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.