Returns the phase error trace of the ModAcc measurement.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string).

    Examples:

    ""

    "signal::sig1"

    "result::r1"

    "signal::sig1/result::r1"

    You can use the RFmxCDMA2k Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • icclst.png Phase Error (deg)

    Phase Error returns the trace of phase errors of the corrected composite signal. This value is expressed in degrees.

  • idbl.png x0

    x0 returns the start time. This value is expressed in seconds.

  • idbl.png dx

    dx returns the chip duration. This value is expressed in seconds.

  • i1dsgl.png y

    y returns the array of phase error values. This value is expressed in degrees.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.