Specifies the ramp time of the burst. The ramp time is the time interval from the time when output power is 40 dB less than the final output power (X dBm) to the time when the output power is +/- 3 dB of the final output power. This value is expressed in seconds. The active packet duration for LE-TP packet is 376 microseconds.

The default value is 2 microseconds. Valid values are from 1 microseconds to 10 microseconds, inclusive.

The following figure shows the power ramp characteristics.

Remarks

The following table lists the characteristics of this property.

Short Name Power Ramp Time (s)
Data type cdbl.png
Permissions Read/Write
High-level VIs niBT SG Set Power Ramp Settling Time, niBT SG Set Power Ramp Time
Resettable No