Fetches an array of transmit power (TXP) measurement results over all the transmit slots of constant tone extension (CTE) portion for low energy (LE) packets when you set the Direction Finding Mode property to Angle of Departure.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and the result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string).

    Example:

    "signal::sig1"

    "result::r1"

    "signal::sig1/result::r1"

    You can use the RFmxBT Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • i1ddbl.png Transmit Slot Average Power Mean (dBm)

    Transmit Slot Average Power Mean returns an array of average powers computed over every transmit slot in CTE portion of the LE packet. When you set the TXP Averaging Enabled property to True, it returns an array of mean of the CTE transmit slot average power results computed for each averaging count. This value is expressed in dBm.

  • i1ddbl.png Transmit Slot Peak Absolute Power Deviation Maximum (%)

    Transmit Slot Peak Absolute Power Deviation Maximum returns an array of peak absolute power deviations computed over every transmit slot in CTE portion of the LE packet. The peak absolute power deviation is the deviation of peak power in each transmit slot with respect to the average power in that transmit slot. When you set the TXP�Averaging�Enabled property to True, it returns an array of maximum of the CTE transmit slot absolute power deviation results computed for each averaging count. This value is expressed as a percentage.

  • ierrcodeclst.png error out