RFmxBT_ACPCfgNumberOfOffsets
- Updated2025-04-08
- 1 minute(s) read
Configures the number of offsets for the adjacent channel power (ACP) measurement.
Syntax
int32 __stdcall RFmxBT_ACPCfgNumberOfOffsets(niRFmxInstrHandle instrumentHandle, char selectorString[], int32 numberOfOffsets)
Parameters
Name | Direction | Type | Description |
---|---|---|---|
instrumentHandle | [in] | niRFmxInstrHandle | This parameter specifies the RFmx session refnum. This parameter is obtained from the RFmxInstr_Initialize function. |
selectorString | [in] | char | This parameter specifies a Selector String comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default value is "" (empty string). |
numberOfOffsets | [in] | int32 | This parameter specifies the number of offset channels used on either side of the reference channel for the ACP measurement when you set the RFMXBT_ATTR_ACP_OFFSET_CHANNEL_MODE attribute to Symmetric. This parameter returns the actual number of offsets used in the ACP measurement when you set the ACP Offset Channel Mode attribute to In-band. The default value is 5. |
Returns
Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. Examine the status code from each call to an RFmx function to determine if an error has occurred.
To obtain a text description of the status code and additional information about the error condition, call the RFmxBT_GetError function.
The general meaning of the status code is as follows:
Value | Meaning |
---|---|
0 | Success |
Positive Values | Warnings |
Negative Values | Errors |