RFmxVnaMX.SetPulseAcquisitionDelay Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Sets the delay in the start of the pulse acquisition relative to the internal pulse trigger when you set the PulseModeEnabled method to True and the PulseAcquisitionAuto method to True . This value is expressed in seconds.
Namespace: NationalInstruments.RFmx.VnaMX
Assembly: NationalInstruments.RFmx.VnaMX.Fx40 (in NationalInstruments.RFmx.VnaMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)
Syntax
public int SetPulseAcquisitionDelay( string selectorString, double value )
Public Function SetPulseAcquisitionDelay ( selectorString As String, value As Double ) As Integer
Parameters
- selectorString String
- Pass an empty string. The signal name that is passed when creating the signal configuration is used.
- value Double
- Specifies the delay in the start of the pulse acquisition relative to the internal pulse trigger when you set the PulseModeEnabled method to True and the PulseAcquisitionAuto method to True . This value is expressed in seconds.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method sets the value of PulseAcquisitionDelay attribute.The default value is 0.