RFmxTdscdmaMXSemResults.FetchLowerOffsetPower Method
- Updated2024-07-17
- 2 minute(s) read
RFmxTdscdmaMXSemResultsFetchLowerOffsetPower Method
Returns the lower offset segment power measurements.
Use "offset(n)" as the selector string to read results from this method.
Use "offset(n)" as the selector string to read results from this method.
Namespace: NationalInstruments.RFmx.TdscdmaMX
Assembly: NationalInstruments.RFmx.TdscdmaMX.Fx40 (in NationalInstruments.RFmx.TdscdmaMX.Fx40.dll) Version: 24.5.0.49284 (24.5.0.49284)
Syntax
public int FetchLowerOffsetPower( string selectorString, double timeout, out double absoluteIntegratedPower, out double relativeIntegratedPower, out double absolutePeakPower, out double peakFrequency, out double relativePeakPower )
Public Function FetchLowerOffsetPower ( selectorString As String, timeout As Double, <OutAttribute> ByRef absoluteIntegratedPower As Double, <OutAttribute> ByRef relativeIntegratedPower As Double, <OutAttribute> ByRef absolutePeakPower As Double, <OutAttribute> ByRef peakFrequency As Double, <OutAttribute> ByRef relativePeakPower As Double ) As Integer
Parameters
- selectorString
- Type: SystemString
Specifies a selector string comprising of the result name, and offset number. If you do not specify the result name, the default result instance is used. - timeout
- Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete. - absoluteIntegratedPower
- Type: SystemDouble
Upon return, contains the lower (negative) offset segment power measured. This value is expressed in dBm. - relativeIntegratedPower
- Type: SystemDouble
Upon return, contains the power in the negative offset segment relative to the integrated power of the reference carrier. This value is expressed in dB. - absolutePeakPower
- Type: SystemDouble
Upon return, contains the peak power measured in the lower (negative) offset segment. This value is expressed in dBm. - peakFrequency
- Type: SystemDouble
Upon return, contains the frequency at which the peak power occurred in the offset segment. This value is expressed in Hz. - relativePeakPower
- Type: SystemDouble
Upon return, contains the peak power in the lower (negative) offset segment relative to the integrated power of the reference carrier.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.