ACP
- Updated2023-10-12
- 3 minute(s) read
ACP
Owning Palette: ConfigurationUse the VIs on this palette to configure adjacent channel power (ACP) measurements. You can also use the RFmxSpecAn Property Node to configure additional properties.
Palette Object | Description |
---|---|
RFmxSpecAn ACP Configure Carrier and Offsets |
Configures a carrier channel with offset channels on both sides of the carrier as specified by the number of offsets. The offset channels are separated by +/- n * channel spacing from the center of the carrier. Power is measured over the integration bandwidth for each channel. |
RFmxSpecAn ACP Configure Number of Carriers |
Configures the number of carriers for the adjacent channel power (ACP) measurement. |
RFmxSpecAn ACP Configure Carrier Mode |
Configures whether to consider the carrier power as part of total carrier power measurement. Use "carrier<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Carrier Offset |
Configures the center frequency of the carrier, relative to the RF center frequency. Use "carrier<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Carrier Integration Bandwidth |
Configures the frequency range, in Hz, over which the measurement integrates the carrier power. Use "carrier<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Carrier RRC Filter |
Configures the root-raised-cosine (RRC) filter to apply on the carrier channel before measuring the carrier channel power. Use "carrier<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Number of Offsets |
Configures the number of offsets for the adjacent channel power (ACP) measurement. |
RFmxSpecAn ACP Configure Offset |
Configures an offset channel on one or both sides of carrier with center to center spacing as specified by the offset frequency and offset frequency definition. In case of multiple carriers, offset frequency is relative to the closest carrier. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Offset Integration Bandwidth |
Configures the frequency range, in Hz, over which the measurement integrates the offset channel power. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Offset Power Reference |
Configures the power reference to use for measuring the relative power of the offset channel. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Offset Relative Attenuation |
Configures the attenuation, in dB, relative to the external attenuation. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Offset RRC Filter |
Configures the root raised cosine (RRC) channel filter to be applied on the offset channel before measuring channel power. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Offset Frequency Definition |
Configures the offset frequency definition for the ACP measurement. Use "offset<n>" as the selector string to configure this VI. |
RFmxSpecAn ACP Configure Power Units |
Configures the units for the absolute power. |
RFmxSpecAn ACP Configure Measurement Method |
Configures the method for performing the adjacent channel power (ACP) measurement. |
RFmxSpecAn ACP Configure Noise Compensation Enabled |
Configures compensation of the channel powers for the inherent noise floor of the signal analyzer. |
RFmxSpecAn ACP Validate Noise Calibration Data |
Indicates whether calibration data is valid for the configuration specified by the signal name in the Selector string parameter. |
RFmxSpecAn ACP Configure RBW Filter |
Configures the resolution bandwidth (RBW) filter. |
RFmxSpecAn ACP Configure Sweep Time |
Configures the sweep time. |
RFmxSpecAn ACP Configure Averaging |
Configures averaging for the adjacent channel power (ACP) measurement. |
RFmxSpecAn ACP Configure FFT |
Configures window and FFT to obtain a spectrum for the adjacent channel power (ACP) measurement. |
RFmxSpecAn Build Carrier String2 |
Creates the carrier string to use as the selector string with the SEM, ACP, and CHP carrier configuration or fetch properties and VIs. |
RFmxSpecAn Build Offset String2 |
Creates the offset string to use as the selector string with SEM and ACP offset configuration or fetch properties and VIs. |
Subpalette | Description |
---|---|
Array VIs |