NF:Cold Source:Input Termination:VSWR Frequency (Hz) Property
- Updated2024-04-10
- 1 minute(s) read
NF:Cold Source:Input Termination:VSWR Frequency (Hz) Property
Short Name: NF Cold Source Input Term VSWR Freq (Hz)
Property of RFmxSpecAn
Specifies an array of frequencies corresponding to the voltage standing wave ratios (VSWR) of the microwave termination used in the cold source method as specified by the NF Cold Source Input Term VSWR property. This value is expressed in Hz.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is an empty array.
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |