DPD:Target Gain Type Property
- Updated2024-04-10
- 2 minute(s) read
DPD:Target Gain Type Property
Short Name: DPD Target Gain Type
Property of RFmxSpecAn
Specifies the gain expected from the DUT after applying DPD on the input waveform.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is Average Gain.
Average Gain (0) |
The DPD polynomial or lookup table is computed by assuming that the linearized gain expected from the DUT after applying DPD on the input waveform is equal to the average power gain provided by the DUT without DPD. |
Linear Region Gain (1) |
The DPD polynomial or lookup table is computed by assuming that the linearized gain expected from the DUT after applying DPD on the input waveform is equal to the gain provided by the DUT, without DPD, to the parts of the reference waveform that do not drive the DUT into non-linear gain-expansion or compression regions of its input-output characteristics. The measurement computes the linear region gain as the average gain experienced by the parts of the reference waveform that are below a threshold which is computed as shown in the following equation: Linear region threshold (dBm) = Max {-25, Min {reference waveform power} + 6, DUT Average Input Power -15} |
Peak Input Power Gain (2) |
The DPD polynomial or lookup table is computed by assuming that the linearized gain expected from the DUT after applying DPD on the input waveform is equal to the average power gain provided by the DUT, without DPD, to all the samples of the reference waveform for which the magnitude is greater than the peak power in the reference waveform (dBm) - 0.5dB. |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |