RFmx SpecAn Properties

Table of Contents

Spectrum:Sweep Time:Auto Property

  • Updated2024-04-10
  • 1 minute(s) read

Spectrum:Sweep Time:Auto Property

Short Name: Spectrum Sweep Time Auto

Property of RFmxSpecAn

Specifies whether the measurement computes the sweep time.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is True.

False (0)

The measurement uses the sweep time that you specify in the Spectrum Sweep Time property.

True (1)

The measurement calculates the sweep time based on the value of the Spectrum RBW property.

Remarks

The following table lists the characteristics of this property.

Datatype ci32.gif
PermissionsRead/Write
High-level VIs RFmxSpecAn Spectrum Configure Sweep Time
ResettableYes