Harm:Auto Setup Enabled Property
- Updated2024-04-10
- 1 minute(s) read
Harm:Auto Setup Enabled Property
Short Name: Harm Harmonics Auto Setup Enabled
Property of RFmxSpecAn
Specifies whether to enable auto configuration of successive harmonics.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is True.
Supported devices: PXIe-5665/5668
False (0) |
The measurement uses manual configuration for the harmonic order, harmonic bandwidth, and harmonic measurement interval. |
True (1) |
The measurement uses the Harm Num Harmonics property and configuration of the fundamental to configure successive harmonics. Bandwidth of Nth order harmonic = N * (Bandwidth of fundamental). Measurement interval of Nth order harmonics = (Measurement interval of fundamental)/N |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | RFmxSpecAn Harm Configure Auto Harmonics |
Resettable | Yes |