RFmx SpecAn Properties

Table of Contents

Harm:Auto Setup Enabled Property

  • Updated2024-04-10
  • 1 minute(s) read

Harm:Auto Setup Enabled Property

Short Name: Harm Harmonics Auto Setup Enabled

Property of RFmxSpecAn

Specifies whether to enable auto configuration of successive harmonics.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is True.

Supported devices: PXIe-5665/5668

False (0)

The measurement uses manual configuration for the harmonic order, harmonic bandwidth, and harmonic measurement interval.

True (1)

The measurement uses the Harm Num Harmonics property and configuration of the fundamental to configure successive harmonics.

Bandwidth of Nth order harmonic = N * (Bandwidth of fundamental).

Measurement interval of Nth order harmonics = (Measurement interval of fundamental)/N

Remarks

The following table lists the characteristics of this property.

Datatype ci32.gif
PermissionsRead/Write
High-level VIs RFmxSpecAn Harm Configure Auto Harmonics
ResettableYes

Log in to get a better experience