RFmxPulseMX.Initiate Method
- Updated2024-07-17
- 1 minute(s) read
RFmxPulseMXInitiate Method
Initiates all enabled measurements. Call this method after configuring the signal and measurement. This method asynchronously launches measurements in the background and immediately returns to the caller program. You can fetch measurement results using the Fetch methods or result methods in the method node. To get the status of measurements, use the RF WaitForMeasurementComplete(String, Double) method or CheckMeasurementStatus(String, Boolean) method.
Namespace: NationalInstruments.RFmx.PulseMX
Assembly: NationalInstruments.RFmx.PulseMX.Fx40 (in NationalInstruments.RFmx.PulseMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int Initiate( string selectorString, string resultName )
Public Function Initiate ( selectorString As String, resultName As String ) As Integer
Parameters
- selectorString
- Type: SystemString
Specifies the result name. The result name can either be specified through this input or the resultName parameter. If you do not specify the result name in this parameter, either the result name specified by the resultName parameter or the default result instance is used. Example:
""
""
"result::r1" - resultName
- Type: SystemString
Specifies the name to be associated with measurement results. Provide a unique name, such as "r1" to enable fetching of multiple measurement results and traces. This input accepts the result name with or without the "result::" prefix. Example:
""
"result::r1"
"r1"
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.