RFmxPulse_CfgSoftwareEdgeTrigger
- Updated2024-10-14
- 1 minute(s) read
RFmxPulse_CfgSoftwareEdgeTrigger
int32 __stdcall RFmxPulse_CfgSoftwareEdgeTrigger (niRFmxInstrHandle instrumentHandle, char selectorString[], float64 triggerDelay, int32 enableTrigger);
Purpose
Configures the device to wait for a software trigger and then marks a reference point within the record.
Parameters
Input | ||
Name | Type | Description |
instrumentHandle | niRFmxInstrHandle | Specifies the instrument session. The RFmx driver obtains this parameter from the RFmxPulse_Initialize function. |
selectorString | char[] | Specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. Example: "signal::sig1" You can use the RFmxPulse_BuildSignalString function to build the selector string. |
triggerDelay | float64 | Specifies the trigger delay time, in seconds. |
enableTrigger | int32 | Specifies whether to enable the trigger. |
Return Value
Name | Type | Description | ||||||||
status | int32 | Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. Examine the status code from each call to an RFmx function to determine if an error has occurred. To obtain a text description of the status code and additional information about the error condition, call the RFmxPulse_GetError function. The general meaning of the status code is as follows:
|
||||||||