RFmxPulse_AbortMeasurements

  • Updated2024-10-14
  • 1 minute(s) read

RFmxPulse_AbortMeasurements

int32 __stdcall RFmxPulse_AbortMeasurements (niRFmxInstrHandle instrumentHandle, char selectorString[]);

Purpose

Stops acquisition and measurements associated with the signal instance that you specify in the selectorString parameter. This acquisition and measurements were previously initiated by the RFmxPulse_Initiate function. Calling this function is optional, unless you want to stop a measurement before it is complete. This function executes even if there is an incoming error.

Parameters

Input
Name Type Description
instrumentHandle niRFmxInstrHandle Specifies the instrument session. The RFmx driver obtains this parameter from the RFmxPulse_Initialize function.
selectorString char[] Specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used.
Example:
"signal::sig1"
You can use the RFmxPulse_BuildSignalString function to build the selector string.

Return Value

Name Type Description
status int32 Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. Examine the status code from each call to an RFmx function to determine if an error has occurred.

To obtain a text description of the status code and additional information about the error condition, call the RFmxPulse_GetError function.

The general meaning of the status code is as follows:

Value Meaning
0 Success
Positive Values Warnings
Negative Values Errors