RFmx NR DotNET

RFmxNRMXModAccResults.FetchCompositeEvm Method

  • Updated2024-07-17
  • 2 minute(s) read
RFmxNRMXModAccResults.FetchCompositeEvm Method

RFmxNRMXModAccResultsFetchCompositeEvm Method

Fetches the composite EVM for ModAcc measurements.
Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read results from this method.

Namespace:  NationalInstruments.RFmx.NRMX
Assembly:  NationalInstruments.RFmx.NRMX.Fx40 (in NationalInstruments.RFmx.NRMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int FetchCompositeEvm(
	string selectorString,
	double timeout,
	out double compositeRmsEvmMean,
	out double compositePeakEvmMaximum
)
Public Function FetchCompositeEvm ( 
	selectorString As String,
	timeout As Double,
	<OutAttribute> ByRef compositeRmsEvmMean As Double,
	<OutAttribute> ByRef compositePeakEvmMaximum As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies a selector string comprising of the result name, subblock number, and carrier number. If you do not specify the result name, the default result instance is used. Example:
"subblock0/carrier0"
"result::r1/subblock0/carrier0"
You can use the BuildCarrierString(String, Int32) method to build the selector string.
timeout
Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.
compositeRmsEvmMean
Type: SystemDouble
Upon return, contains the mean value of the RMS EVMs calculated on all configured channels over the slots specified by the SetMeasurementLength(String, Double) method. When you set the SetEvmUnit(String, RFmxNRMXModAccEvmUnit) method to Percentage, the measurement returns this result as a percentage.When you set the SetEvmUnit(String, RFmxNRMXModAccEvmUnit) method to dB, the measurement returns this result in dB.
compositePeakEvmMaximum
Type: SystemDouble
Upon return, contains the symbol index where the ModAcc maximum peak composite EVM occurs.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.