Component Carrier:Downlink:Mi Configuration Property
- Updated2024-04-10
- 1 minute(s) read
Component Carrier:Downlink:Mi Configuration Property
Short Name: Mi Configuration
Property of RFmxLTE
Specifies whether the Mi parameter is specified by section 6.1.2.6 of 3GPP TS 36.141 specification for testing E-TMs or in the Table 6.9-1 of 3GPP TS 36.211 specification. The Mi parameter determines the number of PHICH groups in each downlink subframe, when you set the Duplex Scheme property to TDD.
This property is not valid, when you set the DL Ch Configuration Mode property to Test Model. The measurement ignores this property, when you set the Link Direction property to Uplink.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is Standard.
Test Model (0) |
Mi parameter is set to 1 as specified in section 6.1.2.6 of 3GPP TS 36.141 specification. |
Standard (1) |
Mi parameter is specified by the Table 6.9-1 of 3GPP TS 36.211 specification. |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |