RFmx LTE DotNET

Table of Contents

RFmxLteMXComponentCarrier.GetPbchPower Method

  • Updated2024-07-17
  • 1 minute(s) read
RFmxLteMXComponentCarrier.GetPbchPower Method

RFmxLteMXComponentCarrierGetPbchPower Method

Gets the power of physical broadcast channel (PBCH) relative to the power of cell-specific reference signal. This value is expressed in dB.

Namespace:  NationalInstruments.RFmx.LteMX
Assembly:  NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int GetPbchPower(
	string selectorString,
	out double value
)
Public Function GetPbchPower ( 
	selectorString As String,
	<OutAttribute> ByRef value As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies the carrier number and subblock number.
Example:
"subblock0" or
"subblock0/carrier0".
You can use the BuildCarrierString(String, Int32) method to build the selector string.
value
Type: SystemDouble
Upon return, contains the power of physical broadcast channel (PBCH) relative to the power of cell-specific reference signal. This value is expressed in dB.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.

Remarks

This method gets the value of PbchPower attribute. The default value is 0.