RFmx LTE DotNET

Table of Contents

RFmxLteMXModAccResults.FetchNPuschDmrsEvm Method

  • Updated2024-07-17
  • 2 minute(s) read
RFmxLteMXModAccResults.FetchNPuschDmrsEvm Method

RFmxLteMXModAccResultsFetchNPuschDmrsEvm Method

Fetches the EVM values calculated on NPUSCH DMRS over the length of the measurement.
Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to configure this method.

Namespace:  NationalInstruments.RFmx.LteMX
Assembly:  NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int FetchNPuschDmrsEvm(
	string selectorString,
	double timeout,
	out double nPuschMeanRMSDmrsEvm,
	out double nPuschMaximumPeakDmrsEvm
)
Public Function FetchNPuschDmrsEvm ( 
	selectorString As String,
	timeout As Double,
	<OutAttribute> ByRef nPuschMeanRMSDmrsEvm As Double,
	<OutAttribute> ByRef nPuschMaximumPeakDmrsEvm As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies a selector string comprising of the result name, subblock number, and carrier number. If you do not specify the result name, the default result instance is used. Example:
"subblock0/carrier0"
"result::r1/subblock0/carrier0"
You can use the BuildCarrierString(String, Int32) method to build the selector string.
timeout
Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.
nPuschMeanRMSDmrsEvm
Type: SystemDouble
Upon return, contains the mean value of the RMS EVMs calculated on the NPUSCH DMRS over the slots specified by the SetMeasurementLength(String, Int32) method.
When you set the SetEvmUnit(String, RFmxLteMXModAccEvmUnit) method to Percentage, the result is returned as a percentage, and when you set the ModAcc EVM Unit method to dB, the result is returned in dB.
nPuschMaximumPeakDmrsEvm
Type: SystemDouble
Upon return, contains the maximum value of the peak EVMs calculated on NPUSCHDMRS over the slots specified by the ModAcc Meas Length method.
When you set the ModAcc EVM Unit method to Percentage, the result is returned as a percentage, and when you set the ModAcc EVM Unit method to dB, the result is returned in dB.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.

See Also

Log in to get a better experience