RFmx GSM Properties

ModAcc:Droop Compensation Enabled Property

  • Updated2023-10-12
  • 1 minute(s) read
 ModAcc:Droop Compensation Enabled Property

ModAcc:Droop Compensation Enabled Property

Short Name: ModAcc Droop Comp Enabled

Property of RFmxGSM

Specifies whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

False (0)

Disables power droop compensation in the EVM measurement.

True (1)

Enables power droop compensation in the EVM measurement.

Remarks

The following table lists the characteristics of this property.

Datatype ci32.gif
PermissionsRead/Write
High-level VIs RFmxGSM ModAcc Configure Droop Compensation Enabled
ResettableYes