RFmxGsmMXModAccResults.GetEvmMaximumPeakPhaseError Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Gets the maximum of peak phase error measured over all timeslots of all acquisitions. This result is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured in degrees.
Namespace: NationalInstruments.RFmx.GsmMX
Assembly: NationalInstruments.RFmx.GsmMX.Fx40 (in NationalInstruments.RFmx.GsmMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)
Syntax
public int GetEvmMaximumPeakPhaseError( string selectorString, out double value )
Public Function GetEvmMaximumPeakPhaseError ( selectorString As String, <OutAttribute> ByRef value As Double ) As Integer
Parameters
- selectorString String
-
Specifies the result name.
Example: ""
"result::r1"
You can use the BuildResultString(String) method to build the selectorString. - value Double
- Upon return, contains the maximum of I/Q gain imbalance values measured over all acquisition time slots. This value is expressed in dB. The presence of quadrature skew in the signal affects the measurement of I/Q gain imbalance.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method gets the value of ModAccResultsEvmMaximumPeakPhaseError attribute.