RFmxGsmMXModAccResults Methods
- Updated2024-07-17
- 9 minute(s) read
RFmx
The RFmxGsmMXModAccResults type exposes the following members.
Methods
Name | Description | |
---|---|---|
![]() | Equals | Determines whether the specified Object is equal to the current Object. (Inherited from Object) |
![]() | FetchConstellationTrace |
Fetches the constellation trace concatenated over all slots for the last acquistion. |
![]() | FetchDemodulatedBits |
Fetches the array of demodulated bits concatenated over all slots for the last acquisition. |
![]() | FetchDetectedTsc |
Fetches the detected training sequence code (TSC) of the last burst for GSM/EDGE/EGPRS. Use "slot(n)" as the selector string to read results from this method. |
![]() | FetchDetectedTscArray |
Fetches the detected training sequence code (TSC) of the last acquisition for GSM/EDGE/EGPRS. |
![]() | FetchEvm |
Fetches the EVM measurement results for EDGE/EGPRS. |
![]() | FetchEvmAmplitudeDroop |
Fetches the amplitude droop measurement results for EDGE/EGPRS. |
![]() | FetchEvmMagnitudeError |
Fetches the RMS values of the magnitude error measurement results for EDGE/EGPRS. |
![]() | FetchEvmPhaseError |
Fetches the phase error measurement results for EDGE/EGPRS. |
![]() | FetchEvmTrace |
Fetches the EDGE/EGPRS RMS EVM trace concatenated over all slots for the last acquisition. |
![]() | FetchIQImpairments |
Fetches the origin offset and gain imbalance measurement results for GSM/EDGE/EGPRS. |
![]() | FetchMagnitudeErrorTrace |
Fetches the EDGE/EGPRS magnitude error trace concatenated over all slots for the last acquisition. |
![]() | FetchPfer |
Fetches the phase and frequency error measurement results for GSM. |
![]() | FetchPhaseErrorTrace |
Fetches the phase error trace concatenated over all slots for the last acquisition. |
![]() | GetDetectedTsc | Gets the detected training sequence code (TSC) if you set the SetBurstSynchronizationType(String, RFmxGsmMXBurstSynchronizationType) method to Tsc. Use "slot(n)" as the selector string to read this result. |
![]() | GetEvm95thPercentileEvm | Gets the EVM value at which no more than 5% of the symbols have an EVM exceeding this value. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvm95thPercentileMagnitudeError | Returns the measured magnitude error value multiplied by 100, at which, no more than 5 percent of the symbols have magnitude error exceeding this value. This result is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured as a percentage. |
![]() | GetEvm95thPercentilePhaseError | Gets the measured phase error value multiplied by 100, at which, no more than 5 percent of the symbols have phase error exceeding this value. This result is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured in degrees. |
![]() | GetEvmMaximumAmplitudeDroop | Gets the maximum of the amplitude droop values measured over all acquisition time slots. This value is expressed in dB/symbol. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMaximumFrequencyError | Gets the maximum of the frequency error values measured over all acquisition time slots. This value is expressed in Hz. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMaximumMagnitudeError | Gets the maximum of the RMS values of magnitude error measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMaximumPeakEvm | Gets the maximum of the peak EVM values measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMaximumPeakMagnitudeError | Gets the maximum of peak magnitude error measured over all timeslots of all acquisitions. This method is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured as a percentage. |
![]() | GetEvmMaximumPeakPhaseError | Gets the maximum of peak phase error measured over all timeslots of all acquisitions. This result is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured in degrees. |
![]() | GetEvmMaximumPhaseError | Gets the maximum of the RMS values of phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMaximumRmsEvm | Gets the maximum of the RMS EVM values measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanAmplitudeDroop | Gets the mean of the amplitude droop values measured over all acquisition time slots. This value is expressed in dB/symbol. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanFrequencyError | Gets the mean of the frequency error values measured over all acquisition time slots. This value is expressed in Hz. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanMagnitudeError | Gets the mean of the RMS values of magnitude error measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanPeakEvm | Gets the mean of the peak EVM values measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanPeakMagnitudeError | Returns the mean of peak magnitude error measured over all timeslots of all acquisitions. This method is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured as a percentage. |
![]() | GetEvmMeanPeakPhaseError | Gets the mean of peak phase error measured over all timeslots of all acquisitions. This result is returned while performing ModAcc measurement on EDGE/EGPRS. This value is measured in degrees. |
![]() | GetEvmMeanPhaseError | Gets the mean of the RMS values of phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmMeanRmsEvm | Gets the mean of the RMS EVM values measured over all acquisition time slots. This value is expressed as a percentage. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetEvmPeakEvmSymbol | Gets the symbol number in the burst measurement interval that corresponds to the EVM value returned by the GetEvmMaximumPeakEvm(String, Double) result. The method returns this result for EDGE/EGPRS measurements. |
![]() | GetHashCode | Serves as a hash function for a particular type. (Inherited from Object) |
![]() | GetMaximumIQGainImbalance | Gets the maximum of I/Q gain imbalance values measured over all acquisition time slots. This value is expressed in dB. The presence of quadrature skew in the signal affects the measurement of I/Q gain imbalance. |
![]() | GetMaximumIQOriginOffset | Gets the maximum of the I/Q origin offset values measured over all acquisition time slots. This value is expressed in dB. Presence of I/Q gain imbalance in the signal affects the I/Q origin offset measurement. The method returns this result for GSM/EDGE/EGPRS measurements. |
![]() | GetMeanIQGainImbalance | Gets the mean of I/Q gain imbalance values measured over all acquisition time slots. This value is expressed in dB. The presence of quadrature skew in the signal affects the measurement of I/Q gain imbalance. |
![]() | GetMeanIQOriginOffset | Gets the mean of the I/Q origin offset values measured over all acquisition time slots. This value is expressed in dB. Presence of I/Q gain imbalance in the signal affects the I/Q origin offset measurement. The method returns this result for GSM/EDGE/EGPRS measurements. |
![]() | GetPfer95thPercentilePhaseError | Gets the measured phase error value multiplied by 100, at which, no more than 5 percent of the symbols have phase error exceeding this value. This result is returned while performing ModAcc measurement on GSM. This value is measured in degrees. |
![]() | GetPferMaximumFrequencyError | Gets the maximum of the frequency error values measured over all acquisition time slots. This value is expressed in Hz. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferMaximumPeakPhaseError | Gets the maximum of peak phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferMaximumRmsPhaseError | Gets the maximum of the RMS phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferMeanFrequencyError | Gets the mean of the frequency error values measured over all acquisition time slots. This value is expressed in Hz. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferMeanPeakPhaseError | Gets the mean of peak phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferMeanRmsPhaseError | Gets the mean of the RMS phase error values measured over all acquisition time slots. This value is expressed in degrees. The method returns this result for GSM ModAcc measurements. |
![]() | GetPferPeakPhaseErrorSymbol | Gets the symbol number in the useful portion of the burst corresponding to the phase error value in the GetPferMaximumPeakPhaseError(String, Double) result. The method returns this result for GSM ModAcc measurements. |
![]() | GetType | Gets the Type of the current instance. (Inherited from Object) |
![]() | ToString | Returns a string that represents the current object. (Inherited from Object) |