PowerRamp:Averaging:Enabled Property
- Updated2024-04-10
- 1 minute(s) read
PowerRamp:Averaging:Enabled Property
Short Name: PowerRamp Averaging Enabled
Property of RFmxBT
Specifies whether to enable averaging for PowerRamp measurement.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is False.
False (0) |
The measurement is performed on a single acquisition. |
True (1) |
The measurement uses the PowerRamp Averaging Count property as the number of acquisitions over which the PowerRamp measurement is averaged. |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |