ACP:Averaging:Enabled Property
- Updated2024-04-10
- 1 minute(s) read
ACP:Averaging:Enabled Property
Short Name: ACP Averaging Enabled
Property of RFmxBT
Specifies whether to enable averaging for the ACP measurement.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is False.
False (0) |
The measurement is performed on a single acquisition. |
True (1) |
The measurement uses the ACP Averaging Count property as the number of acquisitions over which the ACP measurement is averaged. |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |