RFmxEvdoMXSemResults.GetLowerOffsetRelativePeakPower Method
- Updated2024-07-17
- 1 minute(s) read
RFmxEvdoMXSemResultsGetLowerOffsetRelativePeakPower Method
Gets the peak power measured in the lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB. Use "offset(n)" as the selector string to read this method.
Namespace: NationalInstruments.RFmx.EvdoMX
Assembly: NationalInstruments.RFmx.EvdoMX.Fx40 (in NationalInstruments.RFmx.EvdoMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int GetLowerOffsetRelativePeakPower( string selectorString, out double value )
Public Function GetLowerOffsetRelativePeakPower ( selectorString As String, <OutAttribute> ByRef value As Double ) As Integer
Parameters
- selectorString
- Type: SystemString
Specifies the result name and Offset number. Example: "Offset0", "result::r1/Offset0". You can use the BuildOffsetString(String, Int32) method to build the selector string. - value
- Type: SystemDouble
Upon return, contains the peak power measured in the lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB. Use "offset(n)" as the selector string to read this method.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method gets the value of SemResultsLowerOffsetRelativePeakPower attribute.