RFmx EVDO DotNET

Table of Contents

RFmxEvdoMXSemResults.FetchLowerOffsetPower Method

  • Updated2024-07-17
  • 2 minute(s) read
RFmxEvdoMXSemResults.FetchLowerOffsetPower Method

RFmxEvdoMXSemResultsFetchLowerOffsetPower Method

Returns the lower offset segment power measurements. Use "offset(n)" as the selector string to read parameters from this method.

Namespace:  NationalInstruments.RFmx.EvdoMX
Assembly:  NationalInstruments.RFmx.EvdoMX.Fx40 (in NationalInstruments.RFmx.EvdoMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int FetchLowerOffsetPower(
	string selectorString,
	double timeout,
	out double absoluteIntegratedPower,
	out double relativeIntegratedPower,
	out double absolutePeakPower,
	out double peakFrequency,
	out double relativePeakPower
)
Public Function FetchLowerOffsetPower ( 
	selectorString As String,
	timeout As Double,
	<OutAttribute> ByRef absoluteIntegratedPower As Double,
	<OutAttribute> ByRef relativeIntegratedPower As Double,
	<OutAttribute> ByRef absolutePeakPower As Double,
	<OutAttribute> ByRef peakFrequency As Double,
	<OutAttribute> ByRef relativePeakPower As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies a selector string comprising of the result name, and offset number. If you do not specify the result name, the default result instance is used.
timeout
Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.
absoluteIntegratedPower
Type: SystemDouble
Upon return, contains the lower (negative) offset segment power measured. This value is expressed in dBm.
relativeIntegratedPower
Type: SystemDouble
Upon return, contains the power in the lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB.
absolutePeakPower
Type: SystemDouble
Upon return, contains the peak power measured in the lower (negative) offset segment. The power is measured in dBm.
peakFrequency
Type: SystemDouble
Upon return, contains the frequency at which the peak power occurred in the offset segment. This value is expressed in Hz.
relativePeakPower
Type: SystemDouble
Upon return, contains the peak power in the lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.

See Also

Log in to get a better experience