RFmxEvdoMXSemResults.FetchLowerOffsetPowerArray Method
- Updated2024-07-17
- 2 minute(s) read
RFmxEvdoMXSemResultsFetchLowerOffsetPowerArray Method
Returns the arrays of lower offset segment power measurements.
Namespace: NationalInstruments.RFmx.EvdoMX
Assembly: NationalInstruments.RFmx.EvdoMX.Fx40 (in NationalInstruments.RFmx.EvdoMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int FetchLowerOffsetPowerArray( string selectorString, double timeout, ref double[] absoluteIntegratedPower, ref double[] relativeIntegratedPower, ref double[] absolutePeakPower, ref double[] peakFrequency, ref double[] relativePeakPower )
Public Function FetchLowerOffsetPowerArray ( selectorString As String, timeout As Double, ByRef absoluteIntegratedPower As Double(), ByRef relativeIntegratedPower As Double(), ByRef absolutePeakPower As Double(), ByRef peakFrequency As Double(), ByRef relativePeakPower As Double() ) As Integer
Parameters
- selectorString
- Type: SystemString
Specifies a selector string comprising of the result name. If you do not specify the result name, the default result instance is used. - timeout
- Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete. - absoluteIntegratedPower
- Type: SystemDouble
Upon return, contains the array of lower (negative) offset segment powers measured. This value is expressed in dBm. - relativeIntegratedPower
- Type: SystemDouble
Upon return, contains the array of powers in each lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB. - absolutePeakPower
- Type: SystemDouble
Upon return, contains the array of peak powers measured in each lower (negative) offset segment. - peakFrequency
- Type: SystemDouble
Upon return, contains the array of frequencies at which the peak power occurred in each offset segment. This value is expressed in Hz. - relativePeakPower
- Type: SystemDouble
Upon return, contains the array of peak powers in the lower (negative) offset segment relative to the integrated power of the reference carrier. This value is expressed in dB.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.