RFmxDemodMXADemodConfiguration.ConfigureAveraging Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Configures averaging for analog demodulation measurements.
Namespace: NationalInstruments.RFmx.DemodMX
Assembly: NationalInstruments.RFmx.DemodMX.Fx40 (in NationalInstruments.RFmx.DemodMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)
Syntax
public int ConfigureAveraging( string selectorString, RFmxDemodMXADemodAveragingEnabled averagingEnabled, int averagingCount, RFmxDemodMXADemodAveragingType averagingType )
Public Function ConfigureAveraging ( selectorString As String, averagingEnabled As RFmxDemodMXADemodAveragingEnabled, averagingCount As Integer, averagingType As RFmxDemodMXADemodAveragingType ) As Integer
Parameters
- selectorString String
- Pass an empty string. The signal name that is passed when creating the signal configuration is used.
- averagingEnabled RFmxDemodMXADemodAveragingEnabled
- Enables averaging for digital demodulation measurement.
- averagingCount Int32
- Specifies the number of acquisitions used for averaging when you set SetAveragingEnabled(String, RFmxDemodMXADemodAveragingEnabled) to True.
- averagingType RFmxDemodMXADemodAveragingType
- Specifies the averaging type for the measurement.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method maps to the RFmxDemod_ADemodCfgAveraging() function in C.