RFmxDemodMX.SetIQPowerEdgeTriggerLevel Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Sets the power level at which the device triggers. This value is expressed in dB when you set the GetIQPowerEdgeTriggerLevelType(String, RFmxDemodMXIQPowerEdgeTriggerLevelType) to Relative and in dBm when you set the GetIQPowerEdgeTriggerLevelType(String, RFmxDemodMXIQPowerEdgeTriggerLevelType) method to Absolute. The device asserts the trigger when the signal exceeds the level specified by the value of this method, taking into consideration the specified slope. This method is used only when you set the GetTriggerType(String, RFmxDemodMXTriggerType) method to IQ Power Edge.
Namespace: NationalInstruments.RFmx.DemodMX
Assembly: NationalInstruments.RFmx.DemodMX.Fx40 (in NationalInstruments.RFmx.DemodMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)
Syntax
public int SetIQPowerEdgeTriggerLevel( string selectorString, double value )
Public Function SetIQPowerEdgeTriggerLevel ( selectorString As String, value As Double ) As Integer
Parameters
- selectorString String
- Pass an empty string. The signal name passed when creating the signal configuration is used.
- value Double
- Specifies the power level at which the device triggers.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method maps to the RFmxDemod_SetIQPowerEdgeTriggerLevel() function in C.