RFmx CDMA2K DotNET

Table of Contents

RFmxCdma2kMXAcpConfiguration Methods

  • Updated2024-07-17
  • 7 minute(s) read
RFmxCdma2kMXAcpConfiguration Methods

RFmxCdma2kMXAcpConfiguration Methods

The RFmxCdma2kMXAcpConfiguration type exposes the following members.

Methods

 NameDescription
Public methodConfigureAveraging Configures averaging for the ACP measurement.
Public methodConfigureMeasurementMethod Configures the method for performing the ACP measurement.
Public methodConfigureNoiseCompensationEnabled Configures channel power compensation for the inherent noise floor of the signal analyzer.
Public methodConfigureNumberOfOffsets Configures the number of offsets for the ACP measurement.
Public methodConfigureRbwFilter Configures the RBW filter.
Public methodConfigureSweepTime Configures the sweep time.
Public methodEqualsDetermines whether the specified Object is equal to the current Object.
(Inherited from Object)
Public methodGetAllTracesEnabled Gets whether to enable the traces to be stored and retrieved after performing the ACP measurement.
Public methodGetAveragingCount Gets the number of acquisitions used for averaging when you set the SetAveragingEnabled(String, RFmxCdma2kMXAcpAveragingEnabled) method to True.
Public methodGetAveragingEnabled Gets whether to enable averaging for the ACP measurement.
Public methodGetAveragingType Gets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement.
Public methodGetCarrierIntegrationBandwidth Gets the ACP carrier integration bandwidth. This value is expressed in Hz.
Public methodGetFarIFOutputPowerOffset Gets the offset by which to adjust the IF output power level for offset channels that are far from the carrier channel to improve the dynamic range. This value is expressed in dB. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange and set the SetIFOutputPowerOffsetAuto(String, RFmxCdma2kMXAcpIFOutputPowerOffsetAuto) method to False.
Public methodGetFftOverlap Gets the percentage of acquired samples to overlap while performing FFT.
Public methodGetFftOverlapMode Gets how the FFT overlap is applied to the acquired samples.
Public methodGetHashCodeServes as a hash function for a particular type.
(Inherited from Object)
Public methodGetIFOutputPowerOffsetAuto Gets whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange.
Public methodGetMeasurementEnabled Gets whether to enable the ACP measurement.
Public methodGetMeasurementMethod Gets the method for performing the ACP measurement.
Public methodGetNearIFOutputPowerOffset Gets the offset by which to adjust the IF output power level for offset channels that are near the carrier channel to improve the dynamic range. This value is expressed in dB. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange and set the SetIFOutputPowerOffsetAuto(String, RFmxCdma2kMXAcpIFOutputPowerOffsetAuto) method to False.
Public methodGetNoiseCompensationEnabled Gets whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer.
Public methodGetNumberOfAnalysisThreads Gets the maximum number of threads used for parallelism for the ACP measurement.
Public methodGetNumberOfOffsets Gets the number of offset channels.
Public methodGetOffsetFrequency Gets the frequency of an ACP offset channel relative to the carrier frequency. This value is expressed in Hz.
Public methodGetOffsetIntegrationBandwidth Gets the integration bandwidth of an ACP offset channel. This value is expressed in Hz.
Public methodGetRbwFilterAutoBandwidth Gets whether the measurement computes the RBW.
Public methodGetRbwFilterBandwidth Gets the bandwidth of the RBW filter used to sweep the acquired signal when you set the SetRbwFilterAutoBandwidth(String, RFmxCdma2kMXAcpRbwAutoBandwidth) method to False. This value is expressed in Hz.
Public methodGetRbwFilterType Gets the shape of the digital RBW filter.
Public methodGetSequentialFftSize Gets the FFT size, when you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to SequentialFft.
Public methodGetSweepTimeAuto Gets whether the measurement computes the sweep time.
Public methodGetSweepTimeInterval Gets the sweep time when you set the SetSweepTimeAuto(String, RFmxCdma2kMXAcpSweepTimeAuto) method to False. This value is expressed in seconds.
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Public methodSetAllTracesEnabled Sets whether to enable the traces to be stored and retrieved after performing the ACP measurement.
Public methodSetAveragingCount Sets the number of acquisitions used for averaging when you set the SetAveragingEnabled(String, RFmxCdma2kMXAcpAveragingEnabled) method to True.
Public methodSetAveragingEnabled Sets whether to enable averaging for the ACP measurement.
Public methodSetAveragingType Sets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement.
Public methodSetFarIFOutputPowerOffset Sets the offset by which to adjust the IF output power level for offset channels that are far from the carrier channel to improve the dynamic range. This value is expressed in dB. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange and set the SetIFOutputPowerOffsetAuto(String, RFmxCdma2kMXAcpIFOutputPowerOffsetAuto) method to False.
Public methodSetFftOverlapMode Sets how the FFT overlap is applied to the acquired samples.
Public methodSetIFOutputPowerOffsetAuto Sets whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange.
Public methodSetMeasurementEnabled Sets whether to enable the ACP measurement.
Public methodSetMeasurementMethod Sets the method for performing the ACP measurement.
Public methodSetNearIFOutputPowerOffset Sets the offset by which to adjust the IF output power level for offset channels that are near the carrier channel to improve the dynamic range. This value is expressed in dB. This method is used only if you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange and set the SetIFOutputPowerOffsetAuto(String, RFmxCdma2kMXAcpIFOutputPowerOffsetAuto) method to False.
Public methodSetNoiseCompensationEnabled Sets whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer.
Public methodSetNumberOfAnalysisThreads Sets the maximum number of threads used for parallelism for the ACP measurement.
Public methodSetNumberOfOffsets Sets the number of offset channels.
Public methodSetRbwFilterAutoBandwidth Sets whether the measurement computes the RBW.
Public methodSetRbwFilterBandwidth Sets the bandwidth of the RBW filter used to sweep the acquired signal when you set the SetRbwFilterAutoBandwidth(String, RFmxCdma2kMXAcpRbwAutoBandwidth) method to False. This value is expressed in Hz.
Public methodSetRbwFilterType Sets the shape of the digital RBW filter.
Public methodSetSequentialFftSize Sets the FFT size, when you set the SetMeasurementMethod(String, RFmxCdma2kMXAcpMeasurementMethod) method to SequentialFft.
Public methodSetSweepTimeAuto Sets whether the measurement computes the sweep time.
Public methodSetSweepTimeInterval Sets the sweep time when you set the SetSweepTimeAuto(String, RFmxCdma2kMXAcpSweepTimeAuto) method to False. This value is expressed in seconds.
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)
Top

See Also

Log in to get a better experience