RFmxCdma2kMXCdaConfiguration.SetMeasurementLength Method

  • Updated2024-07-17
  • 1 minute(s) read
RFmxCdma2kMXCdaConfiguration.SetMeasurementLength Method

RFmxCdma2kMXCdaConfigurationSetMeasurementLength Method

Sets the duration of code domain measurement. This value is expressed in slots.

Namespace: NationalInstruments.RFmx.Cdma2kMX
Assembly: NationalInstruments.RFmx.Cdma2kMX.Fx40 (in NationalInstruments.RFmx.Cdma2kMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)

Syntax

public int SetMeasurementLength(
	string selectorString,
	int value
)
Public Function SetMeasurementLength ( 
	selectorString As String,
	value As Integer
) As Integer

Parameters

selectorString  String
Pass an empty string. The signal name that is passed when creating the signal configuration is used.
value  Int32
Specifies the duration of code domain measurement. This value is expressed in slots.

Return Value

Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.

Remarks

This method sets the value of CdaMeasurementLength attribute.The default value is 1. The valid values are 1 to 16, inclusive. The sum of the CDA measurement offset and the CDA measurement length must be less than or equal to 16.