RFmx CDMA2K DotNET

Table of Contents

RFmxCdma2kMXSemResults.FetchUpperOffsetPower Method

  • Updated2024-07-17
  • 2 minute(s) read
RFmxCdma2kMXSemResults.FetchUpperOffsetPower Method

RFmxCdma2kMXSemResultsFetchUpperOffsetPower Method

Returns the upper offset segment power measurements.
Use "offset(n)" as the selector string to read parameters from this method.

Namespace: NationalInstruments.RFmx.Cdma2kMX
Assembly: NationalInstruments.RFmx.Cdma2kMX.Fx40 (in NationalInstruments.RFmx.Cdma2kMX.Fx40.dll) Version: 24.5.0.49286 (24.5.0.49286)

Syntax

public int FetchUpperOffsetPower(
	string selectorString,
	double timeout,
	out double absoluteIntegratedPower,
	out double relativeIntegratedPower,
	out double absolutePeakPower,
	out double peakFrequency,
	out double relativePeakPower
)
Public Function FetchUpperOffsetPower ( 
	selectorString As String,
	timeout As Double,
	<OutAttribute> ByRef absoluteIntegratedPower As Double,
	<OutAttribute> ByRef relativeIntegratedPower As Double,
	<OutAttribute> ByRef absolutePeakPower As Double,
	<OutAttribute> ByRef peakFrequency As Double,
	<OutAttribute> ByRef relativePeakPower As Double
) As Integer

Parameters

selectorString  String
Specifies a selector string comprising of the result name, and offset number. If you do not specify the result name, the default result instance is used.
timeout  Double
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.
absoluteIntegratedPower  Double
Upon return, contains the upper (positive) offset segment power measured.
relativeIntegratedPower  Double
Upon return, contains the power in the upper (positive) offset segment relative to the carrier absolute integrated power.
absolutePeakPower  Double
Upon return, contains the peak power measured in the upper (positive) offset segment. The power is measured in dBm.
peakFrequency  Double
Upon return, contains the frequency at which the peak power occurred in the offset segment. This value is expressed in Hz.
relativePeakPower  Double
Upon return, contains the peak power in the upper (positive) offset segment relative to the carrier absolute integrated power.

Return Value

Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.