RFmxCdma2kMXCdaResults Methods
- Updated2024-07-17
- 6 minute(s) read
RFmx
The RFmxCdma2kMXCdaResults type exposes the following members.
Methods
Name | Description | |
---|---|---|
![]() | Equals | Determines whether the specified Object is equal to the current Object. (Inherited from Object) |
![]() | FetchCodeDomainIAndQPower |
Returns the I and Q mean active powers, and I and Q peak inactive powers. |
![]() | FetchCodeDomainIAndQPowerTrace |
Returns the I and Q code power trace measured in the code domain of the base spreading factor. |
![]() | FetchCodeDomainPower |
Returns the scalar code domain power results. |
![]() | FetchIQImpairments |
Returns the measured I/Q impairments. |
![]() | FetchSymbolConstellationTrace |
Returns the symbol constellation trace of the configured measurement channel. |
![]() | FetchSymbolEvm |
Returns the modulation accuracy related measures for the configured measurement channel. |
![]() | FetchSymbolEvmTrace |
Returns the symbol EVM trace of the configured measurement channel. |
![]() | FetchSymbolMagnitudeErrorTrace |
Returns the symbol magnitude error trace of the configured measurement channel. |
![]() | FetchSymbolPhaseErrorTrace |
Returns the symbol phase error trace of the configured measurement channel. |
![]() | FetchSymbolPowerTrace |
Returns the symbol power trace of the configured measurement channel. |
![]() | GetChipRateError | Gets the chip rate error. This value is expressed in parts per million (ppm). |
![]() | GetFrequencyError | Gets the frequency error. This value is expressed in Hz. |
![]() | GetHashCode | Serves as a hash function for a particular type. (Inherited from Object) |
![]() | GetIMeanActivePower | Gets the average power of all active code channels measured on the I-branch. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetIPeakInactivePower | Gets the maximum measured code power among the set of inactive channels on the I-branch and in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetIQGainImbalance | Gets the I/Q gain imbalance of the composite signal averaged over all measured slots. This value is expressed in dB. |
![]() | GetIQOriginOffset | Gets the I/Q origin offset of the composite signal averaged over all measured slots. This value is expressed in dB. |
![]() | GetIQQuadratureError | Gets the I/Q quadrature error of the composite signal averaged over all measured slots. This value is expressed in degrees. |
![]() | GetMeanActivePower | Gets the average power of all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetMeanInactivePower | Gets the average code power, measured among the set of inactive channels, in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetMeanPilotPower | Gets the mean power of the R-PICH.Gets the mean power value in dB, when you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dB.Gets the mean power value in dBm, when you set the CDA Pwr Unit method to dBm. |
![]() | GetMeanSymbolPower | Gets the mean symbol power of the configured measurement channel. This value is expressed in dB, when you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dB, and in dBm, when you set the CDA Pwr Unit method to dBm. |
![]() | GetPeakActivePower | Gets the maximum power among all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetPeakInactivePower | Gets the maximum measured code power, measured among the set of inactive channels, in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetPeakSymbolEvm | Gets the peak symbol EVM of the configured measurement channel. This value is expressed as a percentage. |
![]() | GetQMeanActivePower | Gets the average power of all active code channels measured on the Q-branch. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetQPeakInactivePower | Gets the maximum measured code power among the set of inactive channels on the Q-branch and in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetRmsSymbolEvm | Gets the RMS symbol EVM of the configured measurement channel. This value is expressed as a percentage. |
![]() | GetRmsSymbolMagnitudeError | Gets the RMS symbol magnitude error of the configured measurement channel. This value is expressed as a percentage. |
![]() | GetRmsSymbolPhaseError | Gets the RMS symbol phase error of the configured measurement channel. This value is expressed in degrees. |
![]() | GetTotalActivePower | Gets the sum of the powers of all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method. |
![]() | GetTotalPower | Gets the mean power of the received signal. This value is expressed in dBm. |
![]() | GetType | Gets the Type of the current instance. (Inherited from Object) |
![]() | ToString | Returns a string that represents the current object. (Inherited from Object) |