RFmxCdma2kMXCdaResults Methods

RFmxCdma2kMXCdaResults Methods

The RFmxCdma2kMXCdaResults type exposes the following members.

Methods

 NameDescription
Public methodEqualsDetermines whether the specified Object is equal to the current Object.
(Inherited from Object)
Public methodFetchCodeDomainIAndQPower Returns the I and Q mean active powers, and I and Q peak inactive powers.
Public methodFetchCodeDomainIAndQPowerTrace Returns the I and Q code power trace measured in the code domain of the base spreading factor.
Public methodFetchCodeDomainPower Returns the scalar code domain power results.
Public methodFetchIQImpairments Returns the measured I/Q impairments.
Public methodFetchSymbolConstellationTrace Returns the symbol constellation trace of the configured measurement channel.
Public methodFetchSymbolEvm Returns the modulation accuracy related measures for the configured measurement channel.
Public methodFetchSymbolEvmTrace Returns the symbol EVM trace of the configured measurement channel.
Public methodFetchSymbolMagnitudeErrorTrace Returns the symbol magnitude error trace of the configured measurement channel.
Public methodFetchSymbolPhaseErrorTrace Returns the symbol phase error trace of the configured measurement channel.
Public methodFetchSymbolPowerTrace Returns the symbol power trace of the configured measurement channel.
Public methodGetChipRateError Gets the chip rate error. This value is expressed in parts per million (ppm).
Public methodGetFrequencyError Gets the frequency error. This value is expressed in Hz.
Public methodGetHashCodeServes as a hash function for a particular type.
(Inherited from Object)
Public methodGetIMeanActivePower Gets the average power of all active code channels measured on the I-branch. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetIPeakInactivePower Gets the maximum measured code power among the set of inactive channels on the I-branch and in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetIQGainImbalance Gets the I/Q gain imbalance of the composite signal averaged over all measured slots. This value is expressed in dB.
Public methodGetIQOriginOffset Gets the I/Q origin offset of the composite signal averaged over all measured slots. This value is expressed in dB.
Public methodGetIQQuadratureError Gets the I/Q quadrature error of the composite signal averaged over all measured slots. This value is expressed in degrees.
Public methodGetMeanActivePower Gets the average power of all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetMeanInactivePower Gets the average code power, measured among the set of inactive channels, in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetMeanPilotPower Gets the mean power of the R-PICH.Gets the mean power value in dB, when you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dB.Gets the mean power value in dBm, when you set the CDA Pwr Unit method to dBm.
Public methodGetMeanSymbolPower Gets the mean symbol power of the configured measurement channel. This value is expressed in dB, when you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dB, and in dBm, when you set the CDA Pwr Unit method to dBm.
Public methodGetPeakActivePower Gets the maximum power among all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetPeakInactivePower Gets the maximum measured code power, measured among the set of inactive channels, in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetPeakSymbolEvm Gets the peak symbol EVM of the configured measurement channel. This value is expressed as a percentage.
Public methodGetQMeanActivePower Gets the average power of all active code channels measured on the Q-branch. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetQPeakInactivePower Gets the maximum measured code power among the set of inactive channels on the Q-branch and in the code domain of the base spreading factor. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetRmsSymbolEvm Gets the RMS symbol EVM of the configured measurement channel. This value is expressed as a percentage.
Public methodGetRmsSymbolMagnitudeError Gets the RMS symbol magnitude error of the configured measurement channel. This value is expressed as a percentage.
Public methodGetRmsSymbolPhaseError Gets the RMS symbol phase error of the configured measurement channel. This value is expressed in degrees.
Public methodGetTotalActivePower Gets the sum of the powers of all active code channels. If you set the SetPowerUnit(String, RFmxCdma2kMXCdaPowerUnit) method to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power method.
Public methodGetTotalPower Gets the mean power of the received signal. This value is expressed in dBm.
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)