PDI Error Codes

Code (hex) Additional code Meaning Remedy
0502 Problem with the PDU size Check the call.
Permissible length exceeded. Object cannot be read completely.

Eliminate the hardware error (e.g., I/O voltage not present).

Restart the device.

Contact NI if the problem persists.

0602 Hardware fault Check the call.
0603 Access to object denied
0605 Inconsistent object attributes
0606 The service used cannot be applied to this object.
0607 Object does not exist
0608 Type conflict
0800 xx30

A reserved bit or reserved code was used during parameterization.

xx: Number of the affected elements

30: Value is out of range

Check the parameterization.
0801 Error writing the object Check the call.
Error reading the object
0F01 Hardware or firmware error Restart the device. Contact NI if the problem persists.
0F02
0F03
0F04 Inconsistent parameters Check the parameters.
0F05 PDI object index Invalid parameters Check the parameters.
0F06 PDI object index Access not supported. Check the call.
0F08 PDI object index Maximum number of permitted parallel PDI services exceeded Wait until the services have been processed.
0F0C Unknown Variable_ID Incorrect variable ID for Set_Value or Read_Value. Check the call.
0F0D Internal error Restart the device. Contact NI if the problem persists.
0F11 Device not accessible (bus error). Check the bus configuration.
0F12 Device cannot be reached (timeout). Check the device.
0F13 Device not accessible because it was removed. Check the bus configuration.
0F21 Invalid device number Invalid slot number (Value is 0 or larger than the maximum number of devices) Check the call.
0F22 Invalid device number Slot is not active. Check the call.
0F23 Invalid data length Invalid data length. Check the call.
0F24 Invalid number of parameters Invalid number of parameters. Check the call.
0F31 Internal error Restart the device. Contact NI if the problem persists..
0F32
0F33