Isolation Withstand Voltages

Test section Test voltage
5 V communications power (logic), 24 V supply (I/O) 500 VAC, 50 Hz, 1 min.
5 V supply (logic) / analog inputs 500 VAC, 50 Hz, 1 min.
5 V supply (logic) / functional earth ground 500 VAC, 50 Hz, 1 min.
24 V supply (I/O) / analog inputs 500 VAC, 50 Hz, 1 min.
24 V supply (I/O) / functional earth ground 500 VAC, 50 Hz, 1 min.
Analog inputs / functional earth ground 500 VAC, 50 Hz, 1 min.